The DMF-Z Series is a range of diaphragm pulse valves suitable for dust collector applications, in particular for reverse pulse-jet filter cleaning of filter bags, cartridges, envelope filters, ceramic filters and sintered metal fiber filters. The DMF-Z Series valve has the inlet port at 90° to the outlet port. The DMF-Z Series range comprises 7 models, from ¾″ to 2½″, all with threaded female Gas connections. The ¾″ and 1″ model is in single diaphragm design, while the 1½″, 2″ , 2½″ , 3″ and 4″ are all double diaphragm valves. The special design assures an extremely fast opening time, high flow rates and easy installation. The valves are constructed in die-casting aluminium and have an anodised protection treatment which protect them from corrosive and environmental agents. Bolts and screws are in stainless steel.
Structure & Working Principle
Main Technical Parameters
| Item | Specification |
|---|---|
| Model | DMF-Z-20, DMF-Z-25, DMF-Z-40S, DMF-Z-50S, DMF-Z-62S, DMF-Z-76S, DMF-Z-102S |
| Nominal Pressure | 0.1–0.8 MPa |
| Working Voltage | AC220V, DC24V (common options) |
| Operating Temperature | -25℃ ~ +80℃ |
| Diaphragm Material | Nitrile rubber (NBR) or Viton Rubber |
| Connection Type | Internal thread |
Features
- Compact structure and stable performance, suitable for long-term frequent operation.
- Internal thread connection ensures tight sealing and firm installation.
- Low air resistance, strong pulse blowing force and high cleaning efficiency.
- Dustproof and waterproof design, adaptable to harsh industrial environments.
Application
Pulse Valve Technical Specifications

Precautions before installation of right-angle pulse valve
▼ Clean the interior of the air tank and pipeline to prevent dirt from blocking the damping or exhaust holes;
▼ Check whether the thread size of the blowpipe matches the thread size of the valve installation port; the thread size should be standard pipe thread.
▼ Ensure that the power supply has been cut off and there is no internal pressure in the gas bag;
▼ Pay attention to the direction of the inlet and outlet of the right-angle electromagnetic pulse valve before installation;